Connecting two electrical systems that are not closely matched can cause expensive damage and disturbance to the electrical.
Sync check relay crompton.
When the monitored parameter deviates from the desired set trip limit the relay will operate to prevent damage to power asset.
Syncro check and under over speed trip relay functions.
Various dc models provide protection of battery and ups systems and a range of temperature protection products is ideal to prevent the damaging effects of overheating.
Operate the relay de energises and the sync led goes off.
Crompton supplies protector trip relays and range of electronic control products for electric protection and monitoring.
An extensive range of electronic control products to providing continuous monitoring and protection of any electrical parameter.
Trip relays continuously monitor and protect any electrical parameter within a set point limit.
The synchro check paralleling protector trip relay compares the voltage frequency and phase angle of two supplies and operates a relay according to the state of synchronisation of the supplies.
The relay output can be used for alarm or control purposes.
The following parameters and functions can be measured and controlled by crompton extensive range of analog and digital meters transducers and protectors.
The volt free relay contacts change state when the voltage level phase relationship and frequency are within the selected synchronising limits.
The relay will de energise again and the led will go off when the bus.
The relay can be used to turn on an emergency supply in the event of bus supply failure.
Crompton instruments have been associated with high quality technological developments in all aspects of electrical instrumentation since 1881.
The synchro check relay can be used to assist in the semi automatic parallelling of two ac power systems.
Connecting two electrical systems that a.
Ac and dc volts amps frequency watts vars phase angle power factor synchroscope phase sequence speed indicators elapsed time kilowatt hours temperature thermocouple thermistor rtd meter relays va suppressed zero maximum.
This optional feature enables the relay to energise with a gen supply only thus allowing the generator to power the bus during a supply failure.
The volt free relay contacts change state when the voltage level phase relationship and frequency are within the selected synchronising limits.
The range offers both traditional and technologically advanced products including single parameter units earth leakage protection ground fault relays vector shift and rocof and microprocessor system protection relays.
With dead bus on if the bus voltage falls below the udbon level the relay energises and the dead bus led lights.